Circuit Breaker
Marks 1Marks 2Marks 5
Switch Gear and Protection
Marks 1Marks 2Marks 5
Load Flow Studies
Marks 1Marks 2Marks 5
High Voltage Dc Transmission
Marks 1
Generating Power Station
Marks 1Marks 2
Parameters and Performance of Transmission Lines
Marks 1Marks 2Marks 5
1
GATE EE 2023
MCQ (Single Correct Answer)
+1
-0.33

For the three-bus power system shown in the figure, the trip signals to the circuit breakers B$$_1$$ to B$$_9$$ are provided by overcurrent relays R$$_1$$ to R$$_9$$, respectively, some of which have directional properties also. The necessary condition for the system to be protected for short circuit fault at any part of the system between bus 1 and the R-L loads with isolation of minimum portion of the network using minimum number of directional relays is

GATE EE 2023 Power System Analysis - Switch Gear and Protection Question 1 English

A
R$$_3$$ and R$$_4$$ are directional overcurrent relays blocking faults towards bus 2
B
R$$_3$$ and R$$_4$$ are directional overcurrent relays blocking faults towards bus 2 and R$$_7$$ is directional overcurrent relay blocking faults towards bus 3
C
R$$_3$$ and R$$_4$$ are directional overcurrent relays blocking faults towards Line 1 and Line 2, respectively, R$$_7$$ is directional overcurrent relay blocking faults towards Line 3 and R$$_5$$ is directional overcurrent relay blocking faults towards bus 2
D
R$$_3$$ and R$$_4$$ are directional overcurrent relays blocking faults towards Line 1 and Line 2, respectively.
2
GATE EE 2022
MCQ (Single Correct Answer)
+1
-0.33

The most commonly used relay, for the protection of an alternator against loss of excitation, is

A
offset Mho relay.
B
over current relay.
C
differential relay.
D
Buchholz relay.
3
GATE EE 2011
MCQ (Single Correct Answer)
+1
-0.3
A negative sequence relay is commonly used to protect
A
An alternator
B
A transformer
C
A transmission line
D
A bus bar
4
GATE EE 2008
MCQ (Single Correct Answer)
+1
-0.3
A two machine power system in shown below. Transmission line $$XY$$ has positive sequence impedance of $${Z_1}\Omega $$ and zero sequence impedance of $${Z_0}\Omega $$ GATE EE 2008 Power System Analysis - Switch Gear and Protection Question 16 English
An $$'a'$$ phase to ground fault with zero fault impedance occurs at the centre of the transmission line. Bus voltage at $$X$$ and line current from $$X$$ to $$F$$ for the phase $$'a',$$ are given by $${V_a}$$ Volts and $${{\rm I}_a}$$ Amperes, respectively. Then, the impedance measured by the ground distance relay located at the terminal $$X$$ of line $$XY$$ will be given by
A
$${Z_1}/2\Omega $$
B
$${Z_0}/2\Omega $$
C
$$\left( {{Z_0} + {Z_1}} \right)/2\Omega $$
D
$${V_a}/{{\rm I}_a}\,\Omega $$